MANUAL INSTRUCTION
Technical Specification
Place your cursor here !
Capacity :10000 Ah
Voltage : 5 V
Current : 1 A
Operating Voltage: 5V
Operating Current: 40mA
Response Time : <500ms Insulation Resistance: 100M
Voltage: 5V/3.3V
Current: <20ma
Interface: Analog
Max Contact Rating : 10W
Max Switching Voltage : 220V DC/AC
Max Switching Current : 0.5A
Max Breakdown Voltage : 300V DC/AC
Max Carry Current : 1A
Max Contact Resistance : 100m ohm
Power : Vin, 3.3V, 5V, GND
Analog Pins : A0 – A5
Input/Output Pins : Digital Pins 0 - 13
PWM : 3, 5, 6, 9, 11
​
-
miniature. Starting voltage: DC 4.5V
-
Maximum working current: 15mA (DC 5V)
-
Working voltage: DC 5V ~ 24V
-
Flow range: 1 ~ 30L / min
Vcc : - 0.3 to + 5.5 Volts
All Other Pins : - 0.3 to +5.5 Volts
Pin Input Current : 10mA
Pin Output current : 40mA
Database
API for Monitoring
Emergency Alert
Detail Specification
Note :
-
Frequency of Messaging
-
Every device is only allowed to send 140 messages a day.
-
Sends 96 regular updates (every 15mins)
-
44 updates are allotted for emergency alerts which is sent every 5 mins after the first alert until the conditions cleared
-
-
Broadcast
-
The device sends data every 15 minutes daily but when an emergency happens, it would send the data right away.
-
Alert mode : less 10 Sec (delay)-- email
-
-
Database using MySQL for maintenance/ analysis

Installation Procedure
Install the device at a point on the river where the water level is at least 30cm or at a height where the house of the speed sensor does not touch the river floor. The pole support should be securely anchored on the river floor so that it would not be carried by the river current. The water level during installation should be somewhere in the middle of the tube. For best results, install the device on a day where the water level is considered normal.
The board box can be detached and installed in another location on the river bank. Make sure that the box is high enough so that when the water level rises, the box will not get submerged into the water. The solar cell face should be face up and getting enough sunshine.
.png)
_PNG.png)
Component Assembly
Component Wiring

Operation Mode

-
Normal Mode
The device will send a regular message every 15mins. The message contains the values for the turbidity, speed, level and rain. These values will be updated on the Wix site including the location of the device.
-
Alert Mode
Once the conditions for the alert are met, the device would right away send a message to Losant and which will in turn send an email to the subscribers informing them of the alert. If the conditions persists after 5 mins, it would again send an alert. This would repeat until the conditions returns to normal. If the conditions went back to normal, the device would just return to sending the message every 15 mins.
Troubleshooting
![]() | ![]() | ![]() | ![]() |
---|---|---|---|
![]() | ![]() | ![]() | ![]() |
![]() |